An air cooled chiller and a water cooled chiller are two types of cooling systems that are used in industrial and commercial settings to provide a steady supply of cooled water for various applications such as air conditioning, process cooling, and refrigeration. Both types of chillers use a refrigeration cycle to absorb heat from a process or space and reject it to the environment, but they differ in the method of heat rejection.

An air cooled chiller uses air to dissipate the heat absorbed during the cooling process. It consists of a compressor, a condenser, and an evaporator, which are connected by refrigerant lines. The compressor compresses the refrigerant and raises its temperature, the condenser rejects the heat absorbed by the refrigerant to the air, and the evaporator absorbs heat from the process or space being cooled. The cooled refrigerant then returns to the compressor to begin the cycle again.

Air cooled chillers are typically smaller and less expensive than water cooled chillers. They are also relatively simple to install and maintain, as they do not require a water source or a means of disposing of the heated water. However, they are less efficient and have a lower cooling capacity than water cooled chillers. This is because the efficiency of an air cooled chiller depends on the ambient air temperature and the humidity, which can vary greatly depending on the location and the time of year. Furthermore, as the air cooled chiller is using the ambient air to reject the heat, it is not uncommon for the air cooled chiller to have a lower coefficient of performance (COP) than a water cooled chiller.

On the other hand, a water cooled chiller uses water to dissipate the heat absorbed during the cooling process. It also consists of a compressor, a condenser, and an evaporator, which are connected by refrigerant lines. The compressor compresses the refrigerant and raises its temperature, the condenser rejects the heat absorbed by the refrigerant to the water, and the evaporator absorbs heat from the process or space being cooled. The cooled refrigerant then returns to the compressor to begin the cycle again.

Water cooled chillers are larger and more expensive than air cooled chillers. They also require a reliable water source and a means of disposing of the heated water. However, they are more efficient and have a higher cooling capacity than air cooled chillers. This is because the efficiency of a water cooled chiller does not depend on the ambient air temperature and humidity, but only on the temperature difference between the water and the refrigerant. Additionally, as the water cooled chiller is using water to reject the heat, it often has a higher coefficient of performance (COP) than an air cooled chiller.

In conclusion, the choice between an air cooled chiller and a water cooled chiller depends on the specific application, the location, and the budget. Air cooled chillers are typically smaller, less expensive, and simpler to install and maintain, but they are less efficient and have a lower cooling capacity than water cooled chillers. Water cooled chillers are larger, more expensive, and require a reliable water source and a means of disposing of the heated water, but they are more efficient and have a higher cooling capacity than air cooled chillers.